Trichloroethylene

Data Value
CAS Number(s) 79-01-6
Synonyms Ethylene Trichloride
TCE
Trichloroethene
Triclene
Odor Threshold: if available
DO NOT USE AS A DATA POINT TO DETERMINE OVER EXPOSURE OR NOT UNLESS SPECIFICALLY STATED
> 28 ppm
Relevant Routes of Exposure
Dermal Concern: Likely
Dermal Local Effects: Skin Rash
Dermal Systemic Effects
(affinity for being absorbed into blood stream)
Yes
Inhalation Concern: Yes
Chemical Specific Requirements for TSCA Reform
Regulation: 40 CFR 751 Subpart D
De Minimis Threshold:
(concentration in mixtures where Workplace Chemical Protection Program, WCPP, regulations are not applicable)
0.10%
Action Level for an 8 hour time weighted average (TWA): 0.1 ppm
Existing Chemical Exposure Limit (ECEL) for an 8 Hour Time Weighted Average (TWA): 0.2 ppm TWA
Existing Chemical Exposure Limit (ECEL) for a 15 minute Time Weighted Average (TWA) : Not applicable
Respiratory Protection
Air Purifying Respirator (APR) and Concentration Range

*NOTE* if mist is present, use a combination cartridge consisting of a particulate P 100 + the associated chemical cartridge
Half Face APR (APF 10): 0.2 - 2 ppm organic vapor cartridge
Full Face APR (APF 50): 0.2 - 10 ppm organic vapor cartridge
Full Face (APF 10,000):
Pressure Demand Supplied Air Respirator
≥ 0.1 ppm
Recommended Dermal Protection Information

ALWAYS work with reputable dermal PPE manufacturers for determining recommended chemical gloves and chemical suits. Ensure that ASTM F739 and/or EN 374 are used and followed.
Acceptable Gloves:
for Splash / Intermittent Exposure or Potential for Exposure ≥ 0.3 mm
Butyl
Preferred Gloves:
for Continuous Exposure
8 hr: PVA, Viton, PE/EVAL, Barricade, Trellchem, Tychem, Teflon, Responder
Chemical Suit:
as Determined by a Site Specific Risk Assessment
OSHA Requirements That Still Have to Be Met In Addition to EPA Requirements
Immediately Dangerous To Life or Health (IDLH):
Table of IDLH Values
1000 ppm
OSHA Standard: No
Medical Surveillance: No

Resources