| Data | Value |
|---|---|
| CAS Number(s) |
12001-29-5 |
| Synonyms |
Chrysotile Asbestos White Asbestos |
| Odor Threshold:
if available DO NOT USE AS A DATA POINT TO DETERMINE OVER EXPOSURE OR NOT UNLESS SPECIFICALLY STATED |
Not Applicable |
| Relevant Routes of Exposure | |
| Dermal Concern: | No |
| Dermal Local Effects: | Not Typically Applicable |
| Dermal Systemic Effects
(affinity for being absorbed into blood stream) |
No |
| Inhalation Concern: | Yes |
| Chemical Specific Requirements for TSCA Reform | |
| Regulation: | 40 CFR 751 Subpart F |
| De Minimis Threshold: (concentration in mixtures where Workplace Chemical Protection Program, WCPP, regulations are not applicable) |
|
| Action Level for an 8 hour time weighted average (TWA): | Not Applicable |
| Existing Chemical Exposure Limit (ECEL) for an 8 Hour Time Weighted Average (TWA): | Not Applicable |
| Existing Chemical Exposure Limit (ECEL) for a 15 minute Time Weighted Average (TWA) : | Not Applicable |
| Respiratory Protection Air Purifying Respirator (APR) and Concentration Range *NOTE* if mist is present, use a combination cartridge consisting of a particulate P 100 + the associated chemical cartridge |
|
| Half Face APR (APF 10): | |
| Full Face APR (APF 50): | |
| Full Face (APF 10,000): Pressure Demand Supplied Air Respirator |
|
| Recommended Dermal Protection Information ALWAYS work with reputable dermal PPE manufacturers for determining recommended chemical gloves and chemical suits. Ensure that ASTM F739 and/or EN 374 are used and followed. |
|
| Acceptable Gloves:
for Splash / Intermittent Exposure or Potential for Exposure ≥ 0.3 mm |
As needed for contamination control and associated hazards |
| Preferred Gloves: for Continuous Exposure |
|
| Chemical Suit: as Determined by a Site Specific Risk Assessment |
As determined by site-specific risk assessment |
| OSHA Requirements That Still Have to Be Met In Addition to EPA Requirements | |
| Immediately Dangerous To Life or Health (IDLH): Table of IDLH Values |
See NIOSH IDLH guidance for asbestos |
| OSHA Standard: | Yes 29 CFR 1910.1001 |
| Medical Surveillance: | Yes: Required under OSHA Asbestos Standard when applicable |