Exposure Monitoring Evaluation & Compliance Determination

Compare Monitoring Results to EPA TSCA Exposure Limits (ECELs)

Before you can proceed with the monitoring evaluation, laboratory results must be received. The laboratory results come through a separate sample submission and analysis process.

Laboratory Sampling and Analysis Process

  1. Collect the air sample using the chemical-specific media and calibrated pump.
  2. Record the media ID, pre/post flow rate, sampling time, and sample volume in the Field Sampling Template.
  3. Include required blanks, such as field blanks, based on the analytical method.
  4. Seal and label each sample, then complete a chain-of-custody (COC) / laboratory submission form.
  5. Send samples to an accredited industrial hygiene laboratory using the appropriate NIOSH or OSHA analytical method.
  6. The laboratory analyzes the media and issues a report containing:
    • Chemical concentration or mass detected
    • Reporting and detection limits
    • Units of measurement
    • Blank corrections
    • Analytical method used
    • Quality control information
  7. The industrial hygienist or company auditor uses the result and sampled air volume to determine the employee's TWA or STEL and compares the values to the applicable TSCA-specific requirements.

OSHA describes documenting sampling, submitting samples, and evaluating results against exposure limits in: https://www.osha.gov/otm/section-2-health-hazards/chapter-1


Chain-of-Custody Form

Note: The Field Sampling Template collects field information, but it does not include a chain-of-custody form, laboratory report fields, or final ECEL comparison/compliance determination.

The selected industrial hygiene laboratory normally provides its own chain-of-custody form, either paper or electronic. The individual collecting the samples completes the form and maintains custody until shipment or transfer.

Ask the laboratory for:

  • Industrial hygiene COC/submission form
  • Sampling media and pump requirements
  • Required OSHA/NIOSH analytical method
  • Field blank requirements
  • Packaging, shipping, and holding-time instructions

Use the selected laboratory's chain-of-custody form rather than creating a generic one, unless the laboratory confirms it will accept your company's form.


Step 4 - Exposure Monitoring Evaluation and Compliance Determination

Objective

Evaluate employee exposure monitoring results and compare them to applicable EPA TSCA Exposure Control Evaluation Limits (ECELs) to determine whether employee exposures are adequately controlled or whether additional actions are required.

Required Documentation

Gather the following information before beginning the evaluation: (See Field Sampling Template)

  • Air Monitoring Results
    • Personal breathing zone samples
    • Area samples (if applicable)
    • Short-term samples
    • Full-shift samples
  • Laboratory analytical reports
  • Sampling reports containing:
    • Sample dates
    • Sample duration
    • Employee monitored
    • Work task performed
    • Sampling methodology
  • Existing exposure assessments
  • Engineering control documentation
  • PPE assessments
  • Applicable EPA TSCA risk-management rule requirements
  • Applicable ECEL values

Evaluation Process

1. Identify the Chemical

Document:

  • Chemical Name
  • CAS Number
  • TSCA-Regulated Chemical
  • Process Area Where Used
  • Job Classifications Potentially Exposed

Example:

  • Chemical: Methylene Chloride
  • CAS: 75-09-2
  • Department: Paint Stripping
  • Job Title: Maintenance Technician

2. Identify the Applicable Exposure Limit

Determine:

  • EPA ECEL Value
  • Exposure Averaging Period
  • Short-Term Exposure Limit (STEL), if applicable

Document:

  • Source of Exposure Limit
  • Effective Date of Requirement

Example:

  • ECEL = 2 ppm (8-hour TWA)

3. Review Monitoring Data

For each sample collected, document:

  • Sampling Date
  • Employee Monitored
  • Sample Type
  • Sample Result
  • Units Reported
  • Laboratory Performing Analysis

Example:

Sampling Date Employee Sample Type Result
05/12/2026 J. Smith Personal TWA 1.4 ppm

4. Compare Results to ECEL

Determine whether the exposure result is:

  • Below ECEL
  • Equal to ECEL
  • Above ECEL

Calculation:

Percent of ECEL =
(Monitoring Result ÷ ECEL) × 100

Example:

Monitoring Result = 1.4 ppm
ECEL = 2.0 ppm

Percent of ECEL =
(1.4 ÷ 2.0) × 100

= 70%

Result: ✅ Exposure Below ECEL

5. Perform Statistical Evaluation

Where multiple personal samples exist:

  • Calculate exposure profile
  • Evaluate worker exposure groups
  • Determine upper confidence limits where required
  • Assess variability between employees and tasks

Organizations may use:

  • AIHA Exposure Assessment Tools
  • IHSTAT
  • AIHA Exposure Assessment Strategies
  • Other recognized industrial hygiene statistical methods

Document:

  • Statistical tool used
  • Number of samples analyzed
  • Date analysis completed
  • Person completing analysis

6. Determine Compliance Status

The purpose of this evaluation is to determine whether employee exposure monitoring results comply with the applicable EPA Existing Chemical Exposure Limit (ECEL) and, where applicable, the EPA Short-Term Exposure Limit (EPA STEL).

The facility shall document:

  • Chemical Evaluated
  • Applicable ECEL and/or EPA STEL
  • Sampling Methodology
  • Monitoring Results
  • Statistical Analysis Method Used
  • Exposure Determination
  • Compliance Determination
  • Required Corrective Actions

7. Evaluate Controls

If exposures exceed or approach the ECEL, review:

  • Ventilation Systems
  • Enclosures
  • Local Exhaust Systems
  • Process Modifications
  • Administrative Controls
  • PPE Requirements

Exposure Evaluation Criteria

  • Compare monitored exposure results to the applicable ECEL.
  • Compare short-term results to the applicable EPA STEL, where one exists.
  • Document whether exposure levels are:
    • At or Below Applicable Limits
    • Above Applicable Limits
  • If multiple samples are available, perform a statistical evaluation using recognized industrial hygiene methodologies.
  • Maintain records demonstrating how compliance determinations were made.

8. Corrective Actions

If an ECEL exceedance occurs, document:

  • Cause of Exceedance
  • Immediate Corrective Actions
  • Long-Term Corrective Actions
  • Responsible Person
  • Completion Date
  • Follow-Up Sampling Date

Examples:

  • Install local exhaust ventilation
  • Modify work practices
  • Substitute material
  • Reduce exposure duration
  • Upgrade respiratory protection
  • Increase employee training

ECEL / Maximum Airborne Concentration

EPA describes an ECEL as the maximum airborne concentration that workers may be exposed to without unreasonable risk. Under a Workplace Chemical Protection Program (WCPP), workers should not be exposed above the applicable ECEL and EPA STEL.

Exposure Result Compliance Status
≤ ECEL Compliant
> ECEL Non-Compliant
≤ EPA STEL (if applicable) Compliant
> EPA STEL (if applicable) Non-Compliant

Recommended Auditor Guidance

Percent of ECEL Guidance
< 50% Well Controlled
50% to < 100% Controlled, Continue Monitoring
80% to < 100% Consider Increased Surveillance (Best Practice)
≥ 100% Exceeds ECEL - Corrective Action Required
Any STEL Exceedance Exceeds Regulatory Limit - Corrective Action Required

Compliance Determination

□ Exposure Result ≤ ECEL and ≤ EPA STEL (if applicable)

Status: Compliant

□ Exposure Result > ECEL

Status: Non-Compliant

□ Exposure Result > EPA STEL

Status: Non-Compliant

□ Additional monitoring recommended due to exposure trends approaching the ECEL

Status: Management Review Recommended


Auditor Verification Checklist

Monitoring Review

  • Chemical Identified
  • Applicable ECEL Identified
  • Monitoring Data Available
  • Laboratory Reports Available
  • Employee Exposure Groups Identified

Exposure Evaluation

  • Exposure Results Compared to ECEL
  • Percent of ECEL Calculated
  • Statistical Analysis Completed (if required)
  • Compliance Determination Documented

Control Verification

  • Existing Controls Evaluated
  • PPE Requirements Verified
  • Ventilation Systems Assessed
  • Corrective Actions Documented

Follow-Up

  • Re-Monitoring Completed When Required
  • Exceedances Investigated
  • Records Retained
  • Management Notified of Significant Findings